What we supply
- Hollow metal fire doors — a major commercial-door brand, hollow-metal-door brand, Ceco, Republic, Mesker — at 20, 45, 60, 90, 180-minute ratings
- Fire-rated wood doors — Algoma, Eggers, Mohawk — for architectural applications requiring 20–90-minute ratings
- Fire-rated rolling shutters — every major North American commercial-door brand — at 3-hour and 4-hour ratings for fire compartments and atriums
- Coiling fire counter shutters — for service counters, pharmacies, kitchens, and pass-throughs
- Fire-rated glazing — Vetrotech, SuperLite, FireLite — for visibility-required compartment doors
- Fire-rated assemblies for elevators, stairwells, and shafts — meeting NBC 3.4 and provincial equivalents
Specification depth that protects the AHJ submittal
Every fire-rated door we deliver includes the ULC label showing rating, manufacturer, and listing number; the NFPA 80 manufacturer's installation instructions; the frame anchorage detail (for masonry, drywall, or steel-stud assemblies); and the complete hardware schedule with each component's listing. Doors arrive on site pre-machined for the listed hardware — closer prep, panic prep, electric-hinge prep, viewer prep — so field modifications that void the rating never happen.
Annual NFPA 80 inspection
Once installed, fire doors must be inspected annually by a qualified person per NFPA 80 §5.2. This is mandatory under every Canadian provincial fire code. Our certified inspectors verify label and rating present and legible, frame anchored and undamaged, hinges secured (no missing screws), latching hardware operational, gaskets and intumescent seals in place, glazing intact and rated, self-closing devices working, and drop testing on rolling fire shutters per manufacturer instruction. Findings are documented in writing and any deficiency corrected immediately. Insurance carriers and AHJs routinely audit these records — a missed inspection is a code violation and an insurance gap.
Also called
Specifications and code-compliance documents use a range of names for the same product family: fire rated door, fire rated doors, fire door, fire doors, fire door ratings (referring to the 20/45/60/90/180-minute ratings stamped on the label), fire rated steel door, fire rated steel doors, steel doors fire rated, fire rated wood doors, fire rated wooden doors, fire rated glass doors, fire rated glass in doors, fire rated access doors, fire rated interior door, fire rated interior doors, interior fire rated door, 20 minute fire rated door, and fire rated door for garage (used in firewall-separated parking structures). All carry NFPA 80 / ULC-S104 listing requirements we install to spec.